Filter Results By:

Products

Applications

Manufacturers

Calibration Standards

A qualified quantified source of known value.

See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References


Showing results: 391 - 405 of 411 items found.

  • Mass Flow Controller for Medium Flow

    ​​HFM-201 / HFC-203 - Teledyne Hastings Instruments

    The HFM-201/HFC-203, Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-201 / HFC-203 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Many corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available.

  • Moisture Meters

    PCE Instruments

    Moisture can be found in any material. Even materials considered to be dry have a minor amount of moisture. An imbalance of moisture, whether it be excessive moisture or too little moisture, can cause problems ranging from undesired mold and bacteria growth to cracks and defects. To avoid a moisture imbalance, it is essential to monitor moisture content with a moisture meter that returns accurate and reliable measuring results. A moisture meter can measure the moisture content of everything from the air (relative humidity) to construction and building materials (concrete, wood) to biomass and agricultural products (hay, straw, grain, corn, beans, pellets) to solid waste (pulp, slurry) and beyond. Many moisture meter devices can also measure temperature. The moisture measurement range of each moisture meter varies depending on the model. Some moisture meter products take moisture measurements, store the moisture measurement data to an internal memory or SD cad, and allow the stored moisture measurement data to be transferred to a computer for detailed analysis by means of an evaluation software. PCE Instruments' moisture meter products come factory calibrated. ISO calibration certificates are available optionally for purchase as accessories to most moisture meter models. An ISO calibration certificate may be important to your company in meeting specific quality standards.

  • Load Pull

    Focus Microwaves

    All Focus tuners use extremely efficient calibration and tuning algorithms and control electronics based on LAN control (iTuner). This is a merger our proven tuner technology with state of the art control electronics to create the latest tuner generation. The on-board micro-processor and tuning firmware form a self-contained and fully calibrated test instrument. The micro-processor inside the tuner accepts ASCII format communication, via an industry standard TCP/IP interface, controls up to nine stepper motors (tuner axes) and executes interpolation and tuning functions for single probe (CCMT) tuners (one probe per frequency range). For tuners with more than one independent probe (MPT) covering the same frequency range to allow for harmonic tuning, external computing power is required, because of the exponentially growing number of combinations of tuner states (slug positions).

  • Noise Dose Meters

    PCE Instruments

    Here you will find a full range with an industrial standard noise dose meter to suit every requirement. With the portable noise dose meter you can carry out measurements quickly to gain control of a situation or to set the device to take timed measurements. The noise dose meter is important for all industries, especially by using it as a mobile device which is able to assess office stress levels or street noise levels.Often problems arise from noisy neighbors or if bars and restaurants are in residential areas and produce noise levels after 10pm in excess of what local laws permit. We, of course, can assess which noise dose meter you require in relation to the issue you have and the relating laws. We also have microphone extension cords, tripods, calibrators and calibration certificates for most models of noise dose meter.

  • Bulk Current Monitoring Probe

    MP-50 - FRANKONIA GmbH

    The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.

  • Compact, High-resolution Thermographic Camera

    Ceres T 1280 Series - Xenics

    The Ceres T 1280 series is based upon the Dione 1280 OEM thermal imaging core with 1280×1024 pixels and 12 µm pixel pitch and NETD of less than 50 mK. The camera offers superior on-board thermographic performance (accuracy, stability) in the temperature range up to 400 °C.The Ceres T 1280 camera outputs full frame images at 60 Hz via either a CameraLink or at 45 Hz via GigE Vision interface – all GenICam compliant.The compact size and excellent thermographic stability and accuracy, and GenICam compliant interfacing allow for easy integration in demanding industrial thermography applications.The camera offers one standard option of lens and thermal calibration pack.Benefits & Features• Compact and high-resolution• Superior on-board thermographic performance (stability, accuracy)• GenICam compliant• Uncooled operation

  • Active Monopole Antenna

    AM-741 - Com-Power Corporation

    The 41 inch Monopole antenna is required for making electric field emission measurements below 60 MHz per Military standards (MIL-STD-461) and FAA (DO-160) specifications. This antenna is for emissions measurements only. It cannot be used for transmitting. The Active Monopole antenna is generally used in a shielded room or in a screen room, with the equipment under test (EUT) placed on a metal ground plane. The 41 inch rod and the ground plane behave electrically as though a mirror image of the rod were located below the ground, and the ground removed. Since the stainless steel plate does not have enough surface area to mirror the entire 41 inch rod, it is bonded to the surrounding ground plane during use. The AM-741 is battery powered to prevent measurement errors that maybe caused by external power cables. The ANSI equivalent capacitance substitution (ECSM) method is the recommended method for calibrating AM-741 monopole antenna. The individual calibration data will be included with each antenna.

  • Luminance Colorimeter

    XYL-VI - Lisun Electronics Inc.

    The XYL-VI Luminance Photoelectric Colorimeter changes the traditional structure thoroughly, employs the digital X(λ), Y(λ), Z(λ) sensors to replace the traditional analogue sensors, employs the digital signal measurement system to replace the traditional analogue measurement system. The instrument has no analogue unit, thus it is very simple to overcome the zero drift that is impossible to be avoided in traditional colorimeter. The digital sensor has a large dynamic range. Moreover, it possesses strong anti-interference ability and it has high accuracy. The XYL-VI Luminance Colorimeter contains internal RS232 computer interface. The calibration is done by software. It is suitable for monitoring and remote applications. The XYL-VI Luminance Colorimeter can be calibrated by XYL-VI Luminance Colorimeter software to sample the data and print out the results. It can also be corrected by other standard light sources to obtain very high measuring accuracy of x, y color coordinates and color temperature. It is a real-time measuring system and run under Windows2000/XP.

  • High-Resolution Thermographic Camera

    Ceres T 640 Series - Xenics

    The Ceres T 640 series is based upon the Dione 640 OEM thermal imaging core with 640×480 pixels and 12 µm pixel pitch and NETD of less than 50 mK. The camera offers superior on-board thermographic performance (accuracy, stability) in the temperature range up to 400 °C.The Ceres T 640 camera outputs full frame images at 60 Hz via either a CameraLink or GigE Vision interface – all GenICam compliant.The compact size and excellent thermographic stability and accuracy, and GenICam compliant interfacing allow for easy integration in demanding industrial thermography applications.The camera offers one standard option of lens and thermal calibration pack.The compact Ceres T 640 series find application in process monitoring, medical and scientific and advanced research.Benefits & Features• Compact size and high-performance• Superior on-board thermographic performance (stability, accuracy)• GenICam compliant• Uncooled operation

  • Digital Colorimeter & Illuminance Meter

    CHC-I - Lisun Electronics Inc.

    This Digital Color Meter & Illuminance Meter is based on all digital integral photometric and colorimetric measurement technology. It has no analogue unit, thus it is very simple to overcome the zero drift which is impossible to be avoided in current colorimeter. The digital X (λ), Y (λ), Z (λ) sensor has large dynamic range so that there is no range-changing error in it; moreover, it possesses strong anti-interference ability and high accuracy. The CHC-I contains internal RS232 computer interface, the calibration is done by software. It is suitable for monitoring and remote applications. The CHC-I software can calibrate the instrumentation, sample the data through RS232 interface and print out the results. It can also be calibrated by other standard light sources to obtain very high measuring accuracy of x, y color coordinate and color temperature. It is a real-time measuring system and run under Windows System. 128*64 lattice LCD display, RS232 computer interface and software, Data hold function.

  • Fully Automatic Colorimeter

    DRK103C - Shandong Drick Instruments Co., Ltd.

    (1)5 inch TFT color LCD touch screen, the operation is more humanized, new users can be mastered in a short period of time using the method.(2)Simulation of D65 lighting lighting, using CIE1964 complementary color system and CIE1976 (L*a*b*) color space color difference formula.(3)The motherboard brand new design, using the latest technology, CPU uses 32 bits ARM processor,improve the processing speed, the calculated data is more accurate and rapid electromechanical integration design, abandon cumbersome testing process of the artificial hand wheel is rotated, the real implementation of the test program, a determination of the accurate and efficient.(4)Using d/o lighting and observation geometry, diffuse ball diameter 150mm, diameter of the testing hole is 25mm.(5) A light absorber, eliminate the effect of specular reflection.(6)Add printer and imported thermal printer, without the use of ink and color, no noise when working, fast printing speed.(7) Reference sample can be physical, but also for data,? Can store up to ten only memory reference information.(8) Has the memory function, even if the long-term shutdown loss of power, memory zeroing, calibration, standard sample and a reference sample values of the useful information is not lost.(9) Equipped with a standard RS232 interface, can communicate with computer software.

  • Noise Meters

    PCE Instruments

    Here you will find a full range with an industrial standard noise meter / sound meter to suit every requirement. With the portable noise meter you can carry out measurements quickly to gain control of a situation or to set the sound meter to take timed measurements. The noise meter is important for all industries, especially by using it as a mobile noise meter which is able to assess office stress levels or street noise levels. Often problems arise from noisy neighbors or if bars and restaurants are in residential areas and produce noise levels after 10 pm in excess of what local laws permit. A noise meter / sound meter will help here.We can assess which noise meter or sound meter you require in relation to the issue you have and the relating laws (requirements regarding a sound meter and a sound meter’s usage vary depending on the country). We also have noise meter microphone extension cords, tripods, sound meter calibrators and calibration certificates for most noise meter models.

  • Loss Meter

    L2000 - Appointech, Inc.

    3-in-1 as loss meter, light source, and power meter As loss meter Measure fiber loss at 1310nm and 1550nm As light source Single-head selectable output wavelength of 1310 or 1550 nm Ultra high output stability 0.05dB High output power preset at 0 dBm, or at customer-defined value Selectable CW, 270 Hz, 1KHz or 2KHz modulated output As power meter Calibrated outputs at 850, 1310, 1490, 1550, and 1625nm Data storage, logging, and PC up-loading Interactive measurements via PC Calibration on-site with customer's own standard if needed Selection of relative/absolute power measurement Display measurement in dB, dBm, mW, uW, nW Resolution 0.01dB; absolute accuracy 0.25dB For both single-mode and multi-mode optical fiber Small size, easy for field applications Light weight, less than 0.2Kg Auto power shut-off Enable / Disable Auto laser shut off at above 60oC Rechargeable battery, Battery-full and Battery-low indicator Changeable receptacle connector FC, SC, ST

  • Temperature Data Acquisition

    THERMES-USB - Physitemp Instruments

    Physitemp’s Thermes high accuracy data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. (see THERMES-USB WFI)

  • Gas Analyzers

    Snap-on Inc.

    Independent Handheld 5 Gas Analyzer or use with MODIS™ Link, VERDICT® and VERUS® Bluetooth® link. Fully Portable 5 Gas Analyzer, go anywhere, use anywhere 110 V AC and 12 V powered Internal rechargeable battery, up to one hour of use Ideal for road testing and mobile use Measures exhaust emissions for CO, CO2, HC, O2, NOx and AFR/Lambda Provides an instant assessment of an engine vehicle exhaust and catalytic converter MODIS, VERDICT® and VERUS® Link for enhanced real-time viewing Setup required with included software on USB stick Gather all the evidence required for effective and accurate vehicle diagnostics on one screen in real time View, graph, save and recall data Monitor and reduce vehicle emissions, improve driveability and fuel efficiency There are 255 memory locations in the analyzer to track and print data for the same or many different vehicles Compatible with gasoline, CNG, propane and diesel fuel types Annual calibration and sensor replacement performed at Crystal Lake Northern Repiar enter Meets required industry standard

Get Help